Can I Run This on My Generator?
Check your simultaneous AC loads against your generator’s running and starting watt ratings.
Your inputs
AC device
Total while starting; repeat running W if there is no surge.
Generator comparison
Your generator load check
Compared with the generator watt ratings you entered.
Bars show demand; vertical marks show entered ratings on the same W scale. Red means over the W rating, not a safety assessment.
Watt comparisons and headroom
Enter your generator ratings and the AC loads you want to run together.
Watt ratings alone do not confirm operation or safety. Check startup duration, circuit limits and operating conditions separately.
Edit your inputsHow this calculator works
Formula, worked example, assumptions and sources
The Generator Size Calculator method gives three AC load values: continuous W = sum of quantity × running W; peak with one device starting (W) = continuous W + largest (startup W − running W); and peak with all devices starting together (W) = sum of quantity × startup W. A device’s startup watts are its total power draw while starting, not an extra amount.
Compare continuous load with the generator’s running W rating. Compare each startup scenario with its starting W rating. The displayed difference is entered rating − required W. A positive difference means the load is below the entered watt rating. A negative difference means the load exceeds the rating. Zero means the load is exactly at the limit. For example, a 1,475 W running load, a 2,675 W peak with one device starting, and a 3,175 W peak with all devices starting together compared with 2,000 W running / 3,000 W starting ratings give differences of +525 W, +325 W, and −175 W respectively.
Select the startup scenario that could actually happen. These W ratings alone do not show whether the peak can last long enough or whether voltage, frequency, receptacle current and power factor are compatible. Use actual AC input watts for appliances. Do not treat VA or DC battery draw as the same value. No automatic surge multiplier or safety margin is added.
This comparison does not confirm that your setup will operate safely or correctly. Check startup duration, voltage and frequency, VA/current limits, receptacle and circuit limits, derating, and motor-starting requirements in the generator manual. It does not assess wiring, transfer equipment, fuel use, or exhaust safety.
References: Generac portable generator owner’s manual explains simultaneous running loads and motor startup demand; Champion’s explanation of running and starting W notes that a peak rating lasts only briefly. See the site methodology.
Calculations run in your browser. How your data is used