Generator Size Calculator

Add AC devices that may run together to estimate generator running and starting power.

Where do I find running and startup watts?
Check the device label or manual for electrical input power and starting demand, or use a suitable measurement. Startup watts are the total power while starting, not extra watts; use running watts again if there is no surge. Include only devices that may run together on this source. For a charger, use its AC input, not DC output. Watts, VA and amps are different values; VA or amps alone do not give real watts without the relevant voltage and power factor. If startup watts are unknown, confirm them before relying on the comparison. No startup multiplier is assumed.

AC device 1

Total while starting; repeat running W if there is no surge.

View result

Generator size estimate

Estimated generator output

Continuous AC output for devices running together.

—

Running and startup demand
Running together —
One device starts —
All devices start —

Same W scale. Startup values are separate scenarios; compare their duration with the generator manual.

Compare the load estimates with the generator manual, including surge duration, operating conditions and circuit limits.

Edit your inputs

How this calculator works

Formula, worked example, assumptions and sources

Continuous W = sum of quantity × running W for devices used together. For one device starting while all other devices are already running, add the largest startup W − running W of a single device to continuous W. If all devices start together, sum each device type's quantity × startup W. Startup W is the device's total draw while starting, not extra watts to add twice.

For example, one 1,200 W running / 2,400 W starting air conditioner, two 100 W running / 350 W starting pumps, and a 75 W TV with no surge total 1,475 W running. The one-at-a-time startup peak is 2,675 W; if all devices start together, the peak is 3,175 W. The two peaks describe different assumptions, not two ratings that every generator provides.

Enter AC input watts, not DC battery draw, Wh/day, appliance output ratings, or VA treated as watts. If you only have VA, you need the device's power factor to determine watts. Use startup data from each device's manual or measurement. No generic multiplier or margin is added. The one-at-a-time figure assumes only one device starts while all other devices are already running. Actual starts may overlap. Compare the scenario you expect with the generator's continuous and startup/surge ratings, including their stated conditions and duration. If you already have generator ratings, use Can I Run This on My Generator? for the W comparison.

These are load estimates, not a generator model recommendation or a guarantee that your RV setup will operate correctly. Check the generator's running and starting watt ratings under your expected operating conditions, along with surge duration, voltage, frequency, receptacle and circuit limits, and any derating. This tool does not evaluate wiring, transfer equipment, fuel use, or exhaust safety.

References: Generac portable generator owner’s manual describes adding the largest motor's starting watts to other running loads; Champion explanation of running and starting watts distinguishes sustained output from short surge output. See the site methodology.