Can I Run This on My Inverter?
Check your simultaneous AC loads against your inverter’s continuous and peak watt ratings.
Your inputs
What gets replaced?
Replaces compatible fields, including blanks, with your saved setup. Capacity and unit stay together. Undo is available until you edit a replaced field. Your saved copy stays unchanged. Edit My Setup
AC device
Total while starting; repeat running W if there is no surge.
Inverter comparison
Your inverter load check
Compared with the watt ratings you entered.
Bars show demand; vertical marks show entered ratings on the same W scale. Red means over the W rating, not a safety assessment.
Watt comparisons and headroom
Enter your inverter ratings and the AC loads you want to run together.
Watt ratings alone do not confirm operation or safety. Check surge duration, AC output and battery-side limits separately.
Edit your inputsHow this calculator works
Formula, worked example, assumptions and sources
The Inverter Size Calculator method supplies three load figures: continuous W = sum of quantity × running W; peak with one device starting (W) = continuous W + largest (startup W − running W); and peak with all devices starting together (W) = sum of quantity × startup W. Startup W is the total draw of one device while starting, not an extra amount.
This page compares continuous W with the inverter's entered continuous W rating, then compares each startup scenario with its entered peak W rating. A load equal to the entered rating is shown as being at the limit. For example, 1,400 W running and 2,600 W starting against an inverter rated 2,000 W continuous and 3,000 W peak are 600 W below continuous and 400 W below peak. Check that the inverter can sustain the required startup power for the device's startup duration.
Enter real AC watts on both sides; VA is not interchangeable with W when power factor differs from one. Use the ratings that apply at your operating temperature and check peak duration in the inverter's manual. These W thresholds do not test AC voltage/frequency, current, waveform, or battery-side current. For a generator's running and starting ratings, use the generator check.
This comparison does not confirm that the system will operate safely or correctly. Check surge duration, watt and VA/current limits, output voltage and waveform, and temperature derating. Also confirm that the battery, battery management system (BMS), and wiring can supply the inverter's required DC input. It does not cover shore power or generators.
References: Victron Inverter VE.Direct 120V manual gives continuous and peak W with time limits; Victron inverter selection guidance explains VA versus W, temperature derating, and battery support. See the site methodology.
Calculations run in your browser. How your data is used